Hi,
yes this is possible - define
at^sgpsc="Nmea/Interface","local"
and start GPS by :
at^sgpsc="Engine"," 3"
NMEA frames goes to port when you start GPS.
This is not blocking mode so this means that NMEA frames come but in between you can do AT commands - for example stop GPS by :
AT^SGPSC="Engine","0"
You can also use buffered mode by:
AT^SGPSC="Nmea/Output","buffered"
After ~ 1 minute you got URC:
^SGPSCE: 0,0,31488
later
^SGPSCE: 0,1,39360
which mean that buffer is full - you have to read NMEA by:
AT^SGPSC="Nmea/Output","on"
And later change again to
AT^SGPSC="Nmea/Output","buffered"
or to
AT^SGPSC="Nmea/Output","off"
Also there is possibility to make NMEA output to file - all options are described in ATC.
thnak you to Lukasz for the description and tests.
Regards
ALopez
hi, please can you give some of help? I have EHS8 SDK B80 board with EHS8 eval board, and I don´t have information of ufl connector to GPS, the eval board has 5 ufl connector, what is ufl connector for GPS antenna? and I need information of EHS8 developers.
thank you very much and best kind regras from Guayaquil - Ecuador
Please see this picture: