Thales' cellular IoT products business is now part of Telit Cinterion, find out more.

You are here

EHS6T -JRC Issues | Telit Cinterion IoT Developer Community

February 28, 2017 - 9:28am, 8805 views

I have two EHS6T which have JRC issues:

 

Modem 1: With a HyperTerminal connection to the serial port, on power up I get:

^SYSLOADING

O

 

The ^SYSLOADING would indicate MEM is started, but I am not getting ^SYSSTARTING thus indicating the JRC is not being loaded.

The ‘O’ is just a polling command to external equipment attached to the ASC0 port.

I have tried ‘EHSx gwinswup V03001 arn00000014 to update the Firmware,  depending on flags set I get the following error messages:

·         With No Autostart and No Firmware in Module : Error: cannot send update command.

·         With nothing selected: Warning AT Command mode not selected.

Failed to set userware autostart mode to false.

 

Since there is no JRC I cannot use any AT command to interrogate the modem, or update any settings.

 

The modem is visible in Windows Explorer in Module Disk(A:) along with my MIDlet.

 

The modem was previously working, and the problem appeared after stopping and removing the MIDlet o that I could update the MIDlet.

·         stopping the MIDlet, at^scfg=”Userware/Autostat”,”,””,”0”

·         at^sjam=3,”a:/file.jad”,””

 

 

Modem 2:

This previously also worked.

With a USB connection to the EHS6T and in Windows Explorer the modem is visible via Module Disk (A:), and I can see previous *.jad, *.jar files.

 

With a HyperTerminal connection to the ASC0 com port I get no responses, ^SYSLOADING, ^SYSSTART, from the modem on power-up, and doesn’t respond to user AT commands.

 

I tried to do a Firmware update on this modem, but again on running sgwinswup I get the same error messages as for modem 1 and thus I am unable to get an installed JRC.

 

 

I would appreciate any help in resolving the above issues with both of the modems.

 

Thank you.    

Bobg