Having trouble with EHS6 network registration. | Telit Cinterion IoT Developer Community
February 20, 2017 - 9:44am, 9850 views
Hello,
So i'm working on the EHS6 right now but it looks like it's not registered to a network so i can't send SMS.
AT+CREG =0,2.
AT+CSQ: 99,99
AT^SCFG?
^SCFG: "Audio/Loop","0"
^SCFG: "Call/ECC","0"
^SCFG: "Call/Ecall/AckTimeout","5000"
^SCFG: "Call/Ecall/Callback","0"
^SCFG: "Call/Ecall/CallbackTimeout","43200000"
^SCFG: "Call/Ecall/Msd","0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
^SCFG: "Call/Ecall/Pullmode","0"
^SCFG: "Call/Ecall/SessionTimeout","20000"
^SCFG: "Call/Ecall/StartTimeout","5000"
^SCFG: "Call/Speech/Codec","0"
^SCFG: "GPRS/AutoAttach","enabled"
^SCFG: "Gpio/mode/ASC1","std"
^SCFG: "Gpio/mode/DAI","gpio"
^SCFG: "Gpio/mode/DCD0","gpio"
^SCFG: "Gpio/mode/DSR0","gpio"
^SCFG: "Gpio/mode/DTR0","gpio"
^SCFG: "Gpio/mode/FSR","gpio"
^SCFG: "Gpio/mode/HSIC","rsv"
^SCFG: "Gpio/mode/PULSE","gpio"
^SCFG: "Gpio/mode/PWM","gpio"
^SCFG: "Gpio/mode/RING0","gpio"
^SCFG: "Gpio/mode/SPI","rsv"
^SCFG: "Gpio/mode/SYNC","std"
^SCFG: "Ident/Manufacturer","Cinterion"
^SCFG: "Ident/Product","EHS6"
^SCFG: "MEShutdown/Fso","0"
^SCFG: "MEShutdown/sVsup/threshold","0","0"
^SCFG: "MEopMode/CFUN","0","1"
^SCFG: "MEopMode/Dormancy","0","0"
^SCFG: "MEopMode/SoR","off"
^SCFG: "Radio/Band","511"
^SCFG: "Radio/Mtpl","0"
^SCFG: "Radio/OutputPowerReduction","4"
^SCFG: "Serial/Interface/Allocation","1","1"
^SCFG: "Serial/USB/DDD","0","0","0409","1E2D","0058","Cinterion Wireless Modules","EHx",""
^SCFG: "Tcp/IRT","3"
^SCFG: "Tcp/MR","10"
^SCFG: "Tcp/OT","6000"
^SCFG: "Tcp/WithURCs","on"
^SCFG: "Trace/Syslog/OTAP","0"
^SCFG: "URC/Ringline","local"
^SCFG: "URC/Ringline/ActiveTime","2"
^SCFG: "Userware/Autostart","1"
^SCFG: "Userware/Autostart/Delay","0"
^SCFG: "Userware/DebugInterface","0.0.0.0","0.0.0.0","0"
^SCFG: "Userware/DebugMode","off"
^SCFG: "Userware/Passwd",
^SCFG: "Userware/Stdout","null",,,,"off"
^SCFG: "Userware/Watchdog","0"
OK
I tried of course the SIM card with other devices and it works just fine.
Any ideas ?
Regards
Hello,
The status 5 means that the device is registered at a foreign network. This could also matter here.
Please also check AT&V output.
Regards,
Bartłomiej
AT&V
ACTIVE PROFILE:
E1 Q0 V1 X4 &C1 &D2 &S0 \Q3
S0:000 S3:013 S4:010 S5:008 S6:000 S7:060 S8:000 S10:002
+CBST: 7,0,1
+CRLP: 61,61,78,6
+CR: 0
+CRC: 0
+CMGF: 1
+CSDH: 0
+CNMI: 1,0,0,0,0
+CMEE: 2
+ICF: 3
+DTMF: 0
+CSMS: 0,1,1,1
+CREG: 0,5
+CLIP: 0,2
+COPS: 0,0,"Orange F",2
+CGSMS: 1
OK
I also did
AT^SXRAT?
^SXRAT: 1,2,
***** i tried to force manually a registration to a network to not be in roaming.
AT+COPS=?
+COPS: (1,"Free","Free","20815",2),(1,"Orange F","Orange","20801",2),(1,"Orange F","Orange","20801",0),(3,"F-Bouygues Telecom","BYTEL","20820",2),(3,"F SFR","SFR","20810",0),(3,"F-Bouygues Telecom","BYTEL","20820",0),(3,"F SFR","SFR","20810",2)
AT+COPS=1,2,20815,2
ERROR
AT+COPS=1,2,"20815",2
ERROR
Am i mistaking somewhere ?
Please check the AT+CGSMS command which configures the service for MO (mobile originated) short messages sending. The default value is ans you have configured circuit switched but maybe this network does not support it any more. Please note that sending SMS via Packet Domain is only possible when mobile is attached using AT+CGATT.
Regards,
Bartłomiej
AT+CGSMS?
+CGSMS: 1
OK
AT+CGATT?
+CGATT: 1
OK
i even tried to send sms with CGSMS=2 and it didn't succeeded.
Hello,
As for the manual network registration the second command (AT+COPS=1,2,"20815",2) is correctly formatted. Please set AT+CMEE=2 to possibly see more information about the error.
I'd also suggest to set AT+COPS=0 and check what network will be chosen - if the home network is available the module should register to it.
Is it possible to receive messages or make calls? Did you try to compare the settings of the other device where it is possible to send messages.
Regards,
Bartłomiej
Hello,
Settings are the same with the LR77, there's just one difference is that the module is not registering to the home network and this is why i tried to manually register.
AT+COPS?
+COPS: 0,0,"Orange F",2
OK
AT+COPS=?
+COPS: (1,"Free","Free","20815",2),(2,"Orange F","Orange","20801",2),(1,"Orange F","Orange","20801",0),(3,"F SFR","SFR","20810",2),(3,"F-Bouygues Telecom","BYTEL","20820",2),(3,"F-Bouygues Telecom","BYTEL","20820",0),(3,"F SFR","SFR","20810",0)
the home network is (1,"Free","Free","20815",2).
Regards.
AT+COPS=0 should choose the automatic network registration mode and the module should register to the home network. On the other hand you could register the other device to the same network and compare what if the SMS will not be sent also.
Regards,
Bartłomiej
Hello,
I managed to register in the home network and i'm sending sms now, thank you for your help !
Regards,