Amber LED not blinking | Telit Cinterion IoT Developer Community
December 15, 2016 - 11:31am, 2142 views
Hello,
Is there any significance when the amber LED stays on all the time or off all the time? We have found situations when the module is completed unresponsive and the amber led is either on all the time or off with no blinking.
Thank you.
Hi,
Please check the status of the AT^SLED?
If it is "1", the LED is permanently on during CS calls, voice calls or PS data transfer and also when registered without activity.
If the result is "2", the module will blink sharply (10ms) every 4 seconds when registered and faster during activity.
During limited network service it will blink 500ms on / 500ms off.
Selection "3" is user defined. The blink duration can be chosen between 1 to 50ms.
Best Regards,
Antero
Antero Markkula
Communication and Mechatronics
Enkom Active Oy – www.enkom-active.fi
Upseerinkatu 3 A, 02600 Espoo, Finland
Mobile: +358 400 411368
Office: +358 10 204 0000
Fax: +358 10 204 0010
E-mail: antero.markkula@enkom-active.fi
Hello,
At^sled? results in:
^SLED: 2,10
Thanks.