AT+CALA doesn't work with BGS5/EHS modules | Telit Cinterion IoT Developer Community
June 27, 2016 - 4:31am, 2556 views
Hello all.
I have had some issues trying to port the code from TC65i to BGS5.
I have an application that ***** to use the alarm and I discovered that the AT+CALA exist in the documentations of AT Commands but doens't work in the BGS5. Always when this command is executed the module return error.
The model and fw version are:
Cinterion
BGS5
REVISION 01.100
A-REVISION 00.000.10
Has anyone lived the same issue?
Thanks,
Hello Possebon,
for me it works. Which version of JRC MIDlet do you have?
Here is my test which worked:
Best regards,
Jure
Hello,
This command should work as documented. Please check the AT^SCFG? output for "Userware/Autostart" setting. It should be enabled. There's a factory JRC MIDlet on the module which only starts automatically when the autostart is enabled. As some of the AT commands are implemented in that MIDlet it is possible that this is a source of your problem.
Regards,
Bartłomiej
**** Guys.
I enabled the "Userware/Autostart" and now the command is being executed.
Thanks for your help.