AT^SSRVSET always returns an error | Telit Cinterion IoT Developer Community
March 17, 2016 - 11:33am, 2404 views
Hello,
My current development device is the
Cinterion PLS8-E REVISION 01.429 A-REVISION 01.000.00
it is currently configured for two AT Command Services (default). Regardless of which AT command service I use (application or modem) I can not get a valid response to the AT^SSRVSET command.
AT^SSRVSET?<cr>
AT^SSRVSET? ERROR
AT^SSRVSET="actSrvSet",2 <cr>
AT^SSRVSET="actSrvSet",2 ERROR
AT^SSRVSET="actSrvSet"<cr>
AT^SSRVSET="actSrvSet" ERROR
This is driving me nuts as I need to be able to set the service interface configuration.
I've checked the AT command ports using AT^SQPORT and the response is either 'Application' or 'Modem'.
Is there some other setting I have to enable, or some specific AT command that has to be sent to the modem in order to get a valid response to the AT^SSRVSET command?
Thanks
Hi,
I believe that the AT^SSRVSET command is supported in Rev 02.011 with limitations and
REV 03.003 fully.
The Releases 1.x didn't have that functionality.
I believe your sales contact can help you get the update file.
Best Regards, Antero
Antero Markkula
Communication and Mechatronics
Enkom Active Oy – www.enkom-active.fi
Upseerinkatu 3 A, 02600 Espoo, Finland
Mobile: +358 400 411368
Office: +358 10 204 0000
Fax: +358 10 204 0010
E-mail: antero.markkula@enkom-active.fi
Hello,
You are using the release one sample which does not have this command. It is not possible to update the release 1 hardware to release 2 or 3. Please contact your local distributor to get the newer release sample.
Regards,
Bartłomiej