EHS6 restarts every 12-15seconds | Telit Cinterion IoT Developer Community
June 22, 2015 - 1:17pm, 2408 views
The EHS6 module on our new board restarts every 12-15 seconds, when I am using the ASC0 interface. When I am using the USB interface, everything works fine. What might be wrong?
Some settings:
at^scfg?
^SCFG: "Call/ECC","0"
^SCFG: "GPRS/AutoAttach","enabled"
^SCFG: "Gpio/mode/ASC1","rsv"
^SCFG: "Gpio/mode/DAI","gpio"
^SCFG: "Gpio/mode/DCD0","std"
^SCFG: "Gpio/mode/DSR0","std"
^SCFG: "Gpio/mode/DTR0","std"
^SCFG: "Gpio/mode/FSR","gpio"
^SCFG: "Gpio/mode/HSIC","std"
^SCFG: "Gpio/mode/PULSE","gpio"
^SCFG: "Gpio/mode/PWM","gpio"
^SCFG: "Gpio/mode/RING0","std"
^SCFG: "Gpio/mode/SPI","rsv"
^SCFG: "Gpio/mode/SYNC","std"
^SCFG: "Ident/Manufacturer","Cinterion"
^SCFG: "Ident/Product","EHS6"
^SCFG: "MEShutdown/Fso","0"
^SCFG: "MEopMode/SoR","off"
^SCFG: "Radio/Band","511"
^SCFG: "Radio/OutputPowerReduction","4"
^SCFG: "Serial/Interface/Allocation","1","1"
^SCFG: "Serial/USB/DDD","0","0","0409","1E2D","0058","Cinterion Wireless Modules","EHx",""
^SCFG: "Tcp/IRT","3"
^SCFG: "Tcp/MR","10"
^SCFG: "Tcp/OT","6000"
^SCFG: "Tcp/WithURCs","on"
^SCFG: "Trace/Syslog/Otap","0"
^SCFG: "URC/Ringline","local"
^SCFG: "URC/Ringline/ActiveTime","2"
^SCFG: "Userware/Autostart","1"
^SCFG: "Userware/Autostart/Delay","0"
^SCFG: "Userware/DebugInterface","0.0.0.0","0.0.0.0","0"
^SCFG: "Userware/DebugMode","off"
^SCFG: "Userware/Passwd",
^SCFG: "Userware/Stdout","null",,,,"off"
^SCFG: "Userware/Watchdog","0"
Knut
Hello,
As I understand the problem occurs when the module is connected to the board of your design.
Have you tried voice or data calls? Maybe there is a problem with power supply?
And how about the level converters for ASC0 interface on your board - maybe the voltages of RS232 interface on PC are too high and that's the reason of malfunction.
Do you have any log from the module - is there anything that might be interesting?
Regards,
Bartłomiej
Hello,
The levels on ASC1 were to high, so now it works!
Thank you.
Knut