AT^SQWE=0 will not enter to obex mode on an EHS6T - I got an ERROR | Telit Cinterion IoT Developer Community
March 19, 2015 - 1:48am, 3320 views
With TC65 i it will be "OK"
with EHS6T i got an "ERROR"
WHY?
------------------------------------
^SYSSTART
ati
Cinterion
TC65i
REVISION 02.004
OK
AT^SQWE=0
OK
--ERROR-----------------------------
ati
Cinterion
EHS6
REVISION 02.000
OK
AT^SQWE=0
ERROR
------------------------------
I use TC65sh.jar to copy JAR files from PC to Module. With TC65i it works perfect. With my first EHS6 it will not working...
Hello,
There is no such at command for EHS6 product. You will not find it in the documentation.
In fact for TC65i there is also no such command in the public documentation. It is only for internal purposes.
So if your application is not working with EHS6 you can either try to change the implementation or use AT^SJDL command to download the application to the module. Please see this link:
https://iot-developer.thalesgroup.com/tutorial/python-script-load-files-...
You can also use MES in command mode to automate this process. Please check this:
https://iot-developer.thalesgroup.com/faq/how-load-files-module
Best regards,
Bartłomiej