BGS5T No sms UCR when autostart | Telit Cinterion IoT Developer Community
February 12, 2015 - 3:21pm, 2085 views
SMS UCR works fine while I start my midlet with AT command or trough netbeans. But when I set in project descriptor "Oracle-MIDlet-Autostart" to 1, midlet starts like it should i get SMS on start of midlet, I can use RS232 communication but I don't get any UCR for incoming SMS.
Do I need to change any settings? And could be this conneted with the problem mentioned in other thread that I randomly get ^SCTM_B -1 when listening for UCR's.
Only connected settings that I know, are at the initialization of program and they are:
-AT+cmgf = 1
-AT+CNMI=2,1
-AT^SCTM=1,1
Autostart delay is 60 seconds.
Hello Jure,
Please try to set "Oracle-MIDlet-Autostart" to 2 for your application. This will ensure that your MIDlet will start after the factory JRC MIDlet. And JRC MIDlet is needed to get URC's inside your application.
Regards,
Bartłomiej
It works.
Thank you.
Regards,
Jure