EHS5-E : Can't connect to GPRS network | Telit Cinterion IoT Developer Community
February 11, 2015 - 6:46pm, 3323 views
Hello,
I am currently working with the EHS5-E, and I can't connect to the GPRS network.
Do we need to follow a specific procedure ? I spent some time with the AT command guide, the installation guide, and the Java User guide, but there is so much stuff I'm not sure what is usefull.
at
OK
at+cgdcont?
+CGDCONT: 1,"IP","orange.fr","0.0.0.0",0,0
+CGDCONT: 2,"IP","orange.fr","0.0.0.0",0,0
OK
at+creg?
+CREG: 0,1
OK
at^sici?
^SICI: 0,0,0,"0.0.0.0"
OK
at^sics?
^SICS: 0,"conType","GPRS0"
^SICS: 0,"inactTO","3600"
^SICS: 0,"passwd","*****"
^SICS: 0,"apn","orange.fr"
^SICS: 0,"dns1","193.254.160.1"
^SICS: 1,"conType",""
^SICS: 2,"conType",""
^SICS: 3,"conType",""
^SICS: 4,"conType",""
^SICS: 5,"conType",""
OK
at^scfg?
^SCFG: "Call/ECC","0"
^SCFG: "GPRS/AutoAttach","enabled"
^SCFG: "Gpio/mode/ASC1","rsv"
^SCFG: "Gpio/mode/DAI","std"
^SCFG: "Gpio/mode/DCD0","std"
^SCFG: "Gpio/mode/DSR0","std"
^SCFG: "Gpio/mode/DTR0","std"
^SCFG: "Gpio/mode/FSR","gpio"
^SCFG: "Gpio/mode/PULSE","gpio"
^SCFG: "Gpio/mode/PWM","gpio"
^SCFG: "Gpio/mode/RING0","gpio"
^SCFG: "Gpio/mode/SPI","rsv"
^SCFG: "Gpio/mode/SYNC","gpio"
^SCFG: "Ident/Manufacturer","Cinterion"
^SCFG: "Ident/Product","EHS5-E"
^SCFG: "MEShutdown/Fso","0"
^SCFG: "MEopMode/SoR","off"
^SCFG: "Radio/Band","147"
^SCFG: "Radio/OutputPowerReduction","4"
^SCFG: "Serial/Interface/Allocation","0","0"
^SCFG: "Serial/USB/DDD","0","0","0409","1E2D","0058","Cinterion Wireless Modules","EHx",""
^SCFG: "Tcp/IRT","3"
^SCFG: "Tcp/MR","10"
^SCFG: "Tcp/OT","6000"
^SCFG: "Tcp/WithURCs","on"
^SCFG: "Trace/Syslog/Otap","0"
^SCFG: "URC/Ringline","local"
^SCFG: "URC/Ringline/ActiveTime","2"
^SCFG: "Userware/Autostart","1"
^SCFG: "Userware/Autostart/Delay","0"
^SCFG: "Userware/DebugInterface","0.0.0.0","0.0.0.0","0"
^SCFG: "Userware/DebugMode","on"
^SCFG: "Userware/Passwd",
^SCFG: "Userware/Stdout","asc0",,,,"off"
^SCFG: "Userware/Watchdog","0"
OK
Thanks in advance,
Manfred
Hi,
I can not see the call to open the connection at^siso=<cid>
Are you trying to open the connection with a external PPP stack or just with the AT coomand provided by the module?
If you are using the internet services provided by the module in the following link you can find a nice guideline
https://iot-developer.thalesgroup.com/tutorial/concept-board-internet-se...
Regards
ALopez
Somewhere over the rainbow!!! Looking for the Oz Land!!!